Back

Flow-type air tightness leak detector AL-T90

The air tightness detector works on the principle of filling a sealed cavity with compressed air at a set pressure and detecting whether there is any leakage by measuring the changes in pressure or flow rate inside the workpiece. The instrument is equipped with a high-sensitivity and high-pressure-resistant pressure transmitter and a dedicated pneumatic valve with high sealing performance and reliable operation to form a basic air detection circuit. It features an extremely high test resolution, high detection sensitivity, powerful extended input and output control functions, data recording and statistical analysis functions, multi-channel parameter setting and selection, USB interface data output and other functions. With a full touch screen operation, it is simple and convenient to use, and can conveniently realize the automated testing of the air tightness testing process.

Consultation
Back

Flow-type air tightness leak detector AL-T90

The air tightness detector works on the principle of filling a sealed cavity with compressed air at a set pressure and detecting whether there is any leakage by measuring the changes in pressure or flow rate inside the workpiece. The instrument is equipped with a high-sensitivity and high-pressure-resistant pressure transmitter and a dedicated pneumatic valve with high sealing performance and reliable operation to form a basic air detection circuit. It features an extremely high test resolution, high detection sensitivity, powerful extended input and output control functions, data recording and statistical analysis functions, multi-channel parameter setting and selection, USB interface data output and other functions. With a full touch screen operation, it is simple and convenient to use, and can conveniently realize the automated testing of the air tightness testing process.

Consultation

Parameter channelGroup 100 (0-99)
Refresh rate20Hz
CPU32bit
Power supplyAC 220V ± 10%,50Hz
Test the pressure sourceA clean, dry air source with a pressure not less than 600kPa and over 100kPa higher than the test pressure
Ambient temperatureOperating temperature: 5 to 40°C; -20~-70°C  
TemperatureBelow 80%RH, no condensation
Weight12kg
Time setting0 to 6000 seconds
Standard optional accessories* Balance tank * Leakage calibrator * Standard leakage hole * Test fixture and control system


Test the pressure sourceDisplay accuracy0.1kPa
Display unitKPa, kg/cm2, PSl, mmH20 mmHg, Pa
Sensor range-100/0~100/50/100/400/600
Sensor withstand voltageThree times the pressure of the sensor's full scale
Sensor error± 0.1% F.S.
Leakage volumeDisplay accuracy0.001mlmin, 0.01mlmin, 0.1 ml/min
Sensor range10mL/min, 50mL/min, 200mL/min
Display unitmL/min,mL/s,L/s,m3/h
Sensor withstand voltage350kPa
Sensor error1.00%


13615603507 ScanQRCode