Flow-type air tightness leak detector AL-T90
The air tightness detector works on the principle of filling a sealed cavity with compressed air at a set pressure and detecting whether there is any leakage by measuring the changes in pressure or flow rate inside the workpiece. The instrument is equipped with a high-sensitivity and high-pressure-resistant pressure transmitter and a dedicated pneumatic valve with high sealing performance and reliable operation to form a basic air detection circuit. It features an extremely high test resolution, high detection sensitivity, powerful extended input and output control functions, data recording and statistical analysis functions, multi-channel parameter setting and selection, USB interface data output and other functions. With a full touch screen operation, it is simple and convenient to use, and can conveniently realize the automated testing of the air tightness testing process.
Flow-type air tightness leak detector AL-T90
The air tightness detector works on the principle of filling a sealed cavity with compressed air at a set pressure and detecting whether there is any leakage by measuring the changes in pressure or flow rate inside the workpiece. The instrument is equipped with a high-sensitivity and high-pressure-resistant pressure transmitter and a dedicated pneumatic valve with high sealing performance and reliable operation to form a basic air detection circuit. It features an extremely high test resolution, high detection sensitivity, powerful extended input and output control functions, data recording and statistical analysis functions, multi-channel parameter setting and selection, USB interface data output and other functions. With a full touch screen operation, it is simple and convenient to use, and can conveniently realize the automated testing of the air tightness testing process.
Parameter channel | Group 100 (0-99) | ||||||||||||||||||||||||||||
Refresh rate | 20Hz | ||||||||||||||||||||||||||||
CPU | 32bit | ||||||||||||||||||||||||||||
Power supply | AC 220V ± 10%,50Hz | ||||||||||||||||||||||||||||
Test the pressure source | A clean, dry air source with a pressure not less than 600kPa and over 100kPa higher than the test pressure | ||||||||||||||||||||||||||||
Ambient temperature | Operating temperature: 5 to 40°C; -20~-70°C | ||||||||||||||||||||||||||||
Temperature | Below 80%RH, no condensation | ||||||||||||||||||||||||||||
Weight | 12kg | ||||||||||||||||||||||||||||
Time setting | 0 to 6000 seconds | ||||||||||||||||||||||||||||
Standard optional accessories | * Balance tank * Leakage calibrator * Standard leakage hole * Test fixture and control system |
Test the pressure source | Display accuracy | 0.1kPa | |||||||||||||||||||||||||||
Display unit | KPa, kg/cm2, PSl, mmH20 mmHg, Pa | ||||||||||||||||||||||||||||
Sensor range | -100/0~100/50/100/400/600 | ||||||||||||||||||||||||||||
Sensor withstand voltage | Three times the pressure of the sensor's full scale | ||||||||||||||||||||||||||||
Sensor error | ± 0.1% F.S. | ||||||||||||||||||||||||||||
Leakage volume | Display accuracy | 0.001mlmin, 0.01mlmin, 0.1 ml/min | |||||||||||||||||||||||||||
Sensor range | 10mL/min, 50mL/min, 200mL/min | ||||||||||||||||||||||||||||
Display unit | mL/min,mL/s,L/s,m3/h | ||||||||||||||||||||||||||||
Sensor withstand voltage | 350kPa | ||||||||||||||||||||||||||||
Sensor error | 1.00% |